<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-17 11-41-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.50 MHz 5/5, 72 dBuV
Pilot RDS Phase Difference
0.0 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
0 kHz 1 kHz 19120 0,0105
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-18,0 dBr -18,00 dBr -18,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 43B2 9 (Varied) 1 0 1 0 --:--
RT
-
AF EON
-
FM Scope Max at: 1 kHz MIN: 0 kHz % above 76 kHz: 0,0105 Acquired: 2025/12/17 11.40.49 Total samples: 19120 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 5000 10000 15000
FM Scope MAX: -18,0 dBr MIN: -18,0 dBr AVE: -18,00 dBr % above 12,2 dBr: 0,0 Last value: -18,0 dBr (2025/12/17 11.40.49) 11.26 11.28 11.30 11.32 11.34 11.36 11.38 11.40 -15 -10 -5 0 Pm [dBr]